ADVERTISEMENT

Issue Navigator

Volume 10 No. 01
Earn CME
Accepted Papers
Classifieds







Scientific Investigations

Monitoring Sound To Quantify Snoring and Sleep Apnea Severity Using a Smartphone: Proof of Concept

http://dx.doi.org/10.5664/jcsm.3364

Hiroshi Nakano, Ph.D.1; Kenji Hirayama, Ph.D.1; Yumiko Sadamitsu, R.N.1; Ayaka Toshimitsu, M.T.1; Hisayuki Fujita, M.T.1; Shizue Shin, M.T.1; Takeshi Tanigawa, Ph.D.2
1Sleep Disorders Center, Fukuoka National Hospital, Fukuoka City, Japan; 2Department of Public Health, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan

Study Objectives:

Habitual snoring is a prevalent condition that is not only a marker of obstructive sleep apnea (OSA) but can also lead to vascular risk. However, it is not easy to check snoring status at home. We attempted to develop a snoring sound monitor consisting of a smartphone alone, which is aimed to quantify snoring and OSA severity.

Methods:

The subjects included 50 patients who underwent diagnostic polysomnography (PSG), of which the data of 10 patients were used for developing the program and that of 40 patients were used for validating the program. A smartphone was attached to the anterior chest wall over the sternum. It acquired ambient sound from the built-in microphone and analyzed it using a fast Fourier transform on a real-time basis.

Results:

Snoring time measured by the smartphone highly correlated with snoring time measured by PSG (r = 0.93). The top 1 percentile value of sound pressure level (L1) determined by the smartphone correlated with the ambient sound L1 during sleep determined by PSG (r = 0.92). Moreover, the respiratory disturbance index estimated by the smartphone (smart-RDI) highly correlated with the apnea-hypopnea index (AHI) obtained by PSG (r = 0.94). The diagnostic sensitivity and specificity of the smart-RDI for diagnosing OSA (AHI ≥ 15) were 0.70 and 0.94, respectively.

Conclusions:

A smartphone can be used for effectively monitoring snoring and OSA in a controlled laboratory setting. Use of this technology in a noisy home environment remains unproven, and further investigation is needed.

Commentary:

A commentary on this article appears in this issue on page 79.

Citation:

Nakano H; Hirayama K; Sadamitsu Y; Toshimitsu A; Fujita H; Shin S; Tanigawa T. Monitoring sound to quantify snoring and sleep apnea severity using a smartphone: proof of concept. J Clin Sleep Med 2014;10(1):73-78.




Please login to continue reading the full article

Subscribers to JCSM get full access to current and past issues of the JCSM.

Login to JCSM

Not a subscriber?

Join the American Academy of Sleep Medicine and receive a subscription to JCSM with your membership